WALSN INTERNATIONAL CO., LTD 

Products
Walsn Oxygen Analyser [OAM-800 & OAM-800-R]
    Publish time 2020-02-17 15:13    
Walsn Oxygen Analyser [OAM-800 & OAM-800-R]

Overview

The OAM series are ideal for measuring the continuously oxygen concentration in flue gases of boilers and furnaces. The OAM-800 is the integrated stand-alone oxygen analyser in which the zirconium oxide cell is placed directly in the stream of the products of combustion. The OAM-800-R is designed for remote control. The integrated or remote analyser is reliable for oxygen measurement and features high accuracy and low maintenance.


Product Features

Accurate and reliable measurement, measurment accuracy within 1% range.
Zirconium cell diagnosis function, which is able to check Zirconium cell operation status, as well as prompt
The Zirconum cell boasts a nanoscale coating technology, and platinum welding process to ensure an air tight seal, durable working life and high measurement accuracy
Field repalcement, easy daily maintanence
Able to offer CRTube wear resistant & anti-corrosion protection services, extend the working life



   Specifications

 

Measuring range

0~25%VOL.O2

Zirconia oxide sensor

Suitable for all normal positive and negative flue pressures

Accuracy

±1% of full scale

Zero calibration gas

1%O2 (Background gas :N2)

Repeatability

±0.5% of full scale

analogue outputs

Range calibration gas

8%O2 (Background gas: N2) or

Air

Response time

T0 < 3S,T90 <10S

Gas fl ow

300ml/min (0.64ft3/hr)

Measuring method

Zirconia oxide sensor

Opearting Temperature

-20 ~ +70°C (-4 ~ 158°F)

Probe Material

316L Stainless Steel

Gas Temperature

20 ~ 600°C

IP level

IP65/NMEA4

Power Supply

100 ~ 240VAC, 50 ~60Hz

 

 

Parameters

O2 concentration

Damping

1 ~ 100, optional

Calibration gas

Serial Output

RS485 Modbus protocol

Sensor tempurature

Fault Indication

LED indication and error codes

Fault messages

Calibration

Optional track or hold

Analogue Outputs

Single channel isolated 0~10mA, 0~20mA, 2~20mA, 4~20mA, which can be selected

through the menu.

Probe Length/Weight

0.5m, 6.6Kg; 1.0m, 8.3Kg; 1.2m, 9.1Kg; 1.5m, 13.0Kg; 2.0m, 13.9Kg; 2.5m, 15.8Kg; 3.0m,

16.7Kg

 

Principle

Walsn’s OAM-800 and OAM-800-R oxygen analyser units boast a stable secure zirconia sensor, which consists of zirconium dioxide (ZrO2), and a surface that is coated with a porous plantinum electrode layer. It utilizes a unique platinum welding process to obtain the junction of electrode.

Once consistancy has been achieved,the detected gas enters the inner side tube of the zirconium oxide sensor. At the same time, a sample of the reference gas (Air) enters through the outer side of the sensor.The zirconium oxide sensor will then measure each sample for a potential oxygen concentration difference.

The oxygen concentration reading corresponds with the sensor's temperature and detected gas concentration. Calculations are based on the Nernst Equation.