WALSN INTERNATIONAL CO., LTD 

Products
CMF-TS
    Publish time 2020-02-17 15:34    
CMF-TS

1. Overview
The TS series Coriolis mass flowmeter is a new generation of Coriolis meters with paired triangular flow tubes from Walsn. The Walsn mass flow meter is equipped with a transmitter utilizing a digital signal processor (DSP), integrated with digital closed-loop vibration control (DLC), which performs calculations and monitors diagnostic functions of the sensor. This provides high accuracy measurement, wide range ability and excellent reliability for you. Online node-configuration, diagnostics and data recording can be handled directly through a Hart communicator or Modbus.
The TS Series flowmeter not only provides mass flow rate, but can also calculate: density, temperature volumetric flow rate, total flow and component fractions online and in real-time.

 

2. Features
 Trapezoidal shape amplifies impact of Coriolis force, giving high sensitivity
 Dedicated ASIC with digital closed-loop control (DLC) improves the performance of gas-liquid flow measurement
 Dynamic vibration balance (DVB) technology enhances system stability
 2-point temperature compensation and process pressure compensation

 

3. Applicable Fluids

 Gases  
 Slurries
 Liquids

 

4. Typical Applications

 Custody transfer  
 Reactor feed ratio
 Density measurement  
 Batch control

 

5. Environmental Conditions                       
 Power consumption: ≤ 20W
 Enclosure rating: IP65, IP67, IP68 (Remote Style Options only)
 Vibration limits:
      a) a = 0.5g
      b) Endurance sweep, under the condition of 20Hz ~ 400Hz frequency for 50 sweep cycles
 Impact limits: If the flow meter is well-packed, its performance will not be affected by the following impacts:
      a) Acceleration: 50m/s2
      b) Impact frequency: 60 times/min ~100 times/min
      c) Impact: 1000 times
 Ex approval: Ex d ib IIC T6 Gb
 Electromagnetic/Electrostatic compatibility
      a) Electrostatic discharge: level 3
      b) Electrical fast transient/burst (EFTB) resistance: level 3                         

 

6. Specifications

 

Basic Error

Liquid: ±0.10%;  Gas: ±0.35%;  Liquid density error: ±0.0005g/cm3

Diameter(mm)

DN5~DN80

Anti-explosion

CSA/PCEC/ATEX/IEC

Flange

316L/Titanium/Hastelloy alloy/Other materials required by users

Pressure Rating

10MPa

Material

Measuring tube: 316L, Titanium Alloy

Protection Level

IP65, IP67, IP68 (Remote Style Options only)

Medium Temperature

-40℉~356℉ (-40℃~180℃); -40℉~662℉ (-40℃~350℃); -400℉~662℉ (-240℃~350℃)

Ambient Temperature

-25℃—60℃ (-13℉—140℉) (with LCD); -40℃—85℃ (-40℉—185℉)  (without LCD)

Repeatability

Liquid: ≤0.05%;  Gas: ≤0.17%

Cable for Sensor

10m (The divided type is optional.)

Electronic Connection

M20*1.5 Seal, NPT1/2

Output signal

Analog + Pulse/Frequency; Analog+ Pulse/Frequency + HART; Analog+ PulseFrequency + RS485; Profibus PA/DP; FF; Specially customized